Storage and Backups-Netapp
MetroCluster Check commands shows warnings while system is in switchover state
Issue
When running the metrocluster check command while in the switchover state, some checks return warnings:
ClusterA::> metrocluster check show
Last Checked On: 4/21/2016 07:34:32
Component Result
------------------- ---------
nodes warning
lifs ok
config-replication warning
aggregates ok
clusters ok
5 entries were displayed.
ClusterA::> metrocluster check node show
Last Checked On: 4/21/2016 07:34:32
Node Check Result
--------------------- ------------------------------------ ---------
ClusterA-01
node-reachable ok
metrocluster-ready ok
local-ha-partner ok
ha-mirroring-on ok
ha-mirroring-op-state ok
symmetric-ha-relationship ok
remote-dr-partner ok
dr-mirroring-on warning
dr-mirroring-op-state warning
symmetric-dr-relationship ok
remote-dr-auxiliary-partner ok
symmetric-dr-auxiliary-relationship ok
storage-failover-enabled ok
has-intercluster-lif ok
node-object-limit ok
automatic-uso not-applicable
ClusterA::> metrocluster check config-replication show -instance
Enabled: true
Running: true
Recovery Steps: -
Remote Heartbeat: ok
Last Heartbeat Sent: 4/21/2016 08:20:32
Last Heartbeat Received: 4/21/2016 08:19:57
Recovery Steps: -
Storage Status: ok
Storage In Use: Cluster-wide Volume: MDV_CRS_1fa20d6af0df11e5942100a0985bb98a_A
Storage Remarks: -
Recovery Steps: -
Vserver Streams: warning
Recovery Steps: Run the "metrocluster vserver show" command for more details.
Cluster Streams: warning
Recovery Steps: Contact technical support for assistance.
Aggregate creation fails in a MetroCluster with error: An aggregate already uses aggr0 as name
Issue
-
Aggregate creation fails with error
Error: command failed: An aggregate already uses <duplicate aggr name> as name
How to create unique aggregate names in a MetroCluster
Description
This Article describes how to create unique aggregate names if accidently duplicate aggregate names got created.
Is Dynamic POD Licensing supported in Fabric MetroCluster or Brocade switches
Applies to
-
MetroCluster
-
ONTAP 9
-
Brocade
Question(s) and Answer(s)
Is Dynamic POD Licensing supported in Fabric MetroCluster for Brocade switches?
-
Dynamic Licensing is supported in MetroCluster starting Ontap 9
-
Dynamic Licensing is not supported in 7mode MetroCluster
Is Dynamic POD Licensing supported in Fabric MetroCluster for Brocade switches?
-
Dynamic Licensing is supported in MetroCluster starting Ontap 9
-
Dynamic Licensing is not supported in 7mode MetroCluster
Should nodes in a MetroCluster DR Group be of the same controller type?
Question(s) and Answer(s)
Should nodes in a MetroCluster DR Group be of the same controller type?
In Data ONTAP, the controller forming a High Availability (HA) pair or a MetroCluster has to be of the same type.
If the system consists of different types, contact your NetApp Sales Representative to resolve the issue.
Should nodes in a MetroCluster DR Group be of the same controller type?
In Data ONTAP, the controller forming a High Availability (HA) pair or a MetroCluster has to be of the same type.
If the system consists of different types, contact your NetApp Sales Representative to resolve the issue.
Controller continually placed offline by alternate
Applies to
Controller: 2660
Firmware Version: 07.75.36.30
Issue
Add your text here.